Sensory Elements and Devices Operational Diagnostic Blood Glucose

Authors

  • I.T. Kogut Vasyl Stefanyk Precarpathian National University
  • M.V. Kotyk Vasyl Stefanyk Prekarpathian University

DOI:

https://doi.org/10.15330/pcss.17.1.108-113

Keywords:

diabetes, sensors, invasive and noninvasive methods, blood glucose levels

Abstract

The problem of monitoring diabetes is caused as a significant prevalence of the disease, and development on this basis of complex related complications, early disability and mortality. [1] So important is operational and continuous monitoring of blood glucose (MBG), which will increase rates treatment of diabetes.

Currently developed compact diagnostic system CMG for both the clinic and personal use. These systems are the most invasive, requiring immediate blood sampling. At the same time, become of diagnostic devices which are based on non-invasive method that the accuracy inferior invasive, but is more promising, because they have more functionality in terms of ease of measurement, storage and processing results. These systems include a measuring device and sensor elements. This paper will review methods and analysis of the basic principles of measurement devices MBG to develop circuit solutions for the creation of sensor and microsystem elements for noninvasive monitoring MBG.

References

[1] E. G. Butolin, V. G. Ivanov, Klinicheskaja informativnost' pokazatelej biologicheskih zhidkostej organizma (Izhevsk, Jekspertiza, 1998).
[2] V. L. Gerasimenko, Obzor metodov opredelenija gljukozy (Nauka, Moskva, 2005).
[3] Y. Kim, S. Hahn and G. Yoon, Determination of Glucose in Whole Blood Samples by Mid-Infrared Spectroscopy (Appl. Opt. 2003).
[4] El. Wilkins, P. Atanasov, Glucose monitoring: state of the art and future possibilities (Med Eng Phys. 1996).
[5] PU Abel, T. von Woedtke, Biosensors for in vivo glucose measurement: can we cross the experimental stage, (Biosens, Bioelectron, 2002).
[6] S. Zimmermann, D. Fienbork, B. Stoeboer, A. W. Flounders, D. Liepmann, A Microneedle-Based Glucose Monitor: Fabricated on a Wafer-Level Using in-Device Enzyme Immobilization. Pro ceedings of the 12th International Conference on Solid State Sensors, (Actuators and Microsystems; Boston, MA, USA. 2003).
[7] Y. Mendelson, J. D. Bronzino, Optical Sensors in The Biomedical Engineering Handbook (Boca Raton, 1995).
[8] M. D. Ilana Harman-Boehm, A. Gal, A. M. Raykhman, Eugene Naidis, and Y. Mayzel, Noninvasive Glucose Monitoring: Increasing Accuracy by Combination of Multi-Technology and Multi-Sensors, (Journal of Diabetes Science and Technology Volume 4, Issue 3, May 2010).